Data Centers
Secure, redundant and highly available infrastructure for your operation.
ServHost has infrastructure in data centers prepared to deliver security, performance and high availability for corporate environments. Our structure is designed to keep critical operations always active, with redundant networks, continuous monitoring, protection against failures and specialized support.
With a strategic presence in Brazil, the United States and Europe, we offer low latency, excellent connection routes and the reliability needed to host applications, servers, systems and projects that require stability and continuity.
- Dallas
The DFW1 data center in Dallas, located in the former Federal Reserve building, is connected to the same protected power grid as the Dallas 911 emergency service and local hospitals.
- Power redundancy
N+1
- Cooling redundancy
N+1
- On-site security
Electronic security using access cards and biometrics, a security team on duty 24 hours a day, 7 days a week, and closed-circuit cameras throughout the facility.
- Certificates
PCI-DSS, SSAE, SOC 1 Type II, SOC 2 Type II
- Power redundancy
- João Pessoa
In Brazil, we operate two Tier III certified data centers: João Pessoa, in the northeast, and São Paulo, in the southeast.
- Power redundancy
The total installation has a power generation capacity of 1.5 MW, with two substations on site supplied by local utility Eletrobras.
- Cooling redundancy
400 tons of independent air cooling systems with intelligent pre-cooling that saves water when ambient temperatures rise above 30°C.
- On-site security
Comprehensive 24/7/365 video surveillance systems with automatic motion detection in high definition and storage of digital recordings for more than 90 days.
- Power redundancy
- United Kingdom
The data center offers robust solutions for companies, with world-leading efficiency and London connectivity of less than 0.4 ms.
- Power redundancy
Power generation capacity of 3000 kW, two main medium-voltage switchboards, 11 kV distribution and UPS capacity of 1500 kW.
- Cooling redundancy
2N air handling units, UPS cooling: N + N CRAH units and battery cooling: N + N DX units
- On-site security
Complete 24/7 on-site and perimeter security, CCTV surveillance, security gate access, access cards and biometrics.
- Power redundancy
- São Paulo
In Brazil, we operate two Tier III certified data centers: João Pessoa, in the northeast, and São Paulo, in the southeast.
- Power redundancy
The total installation has a power generation capacity of 1.5 MW, with two substations on site supplied by local utility Eletrobras.
- Cooling redundancy
400 tons of independent air cooling systems with intelligent pre-cooling that saves water when ambient temperatures rise above 30°C.
- On-site security
Comprehensive 24/7/365 video surveillance systems with automatic motion detection in high definition and storage of digital recordings for more than 90 days.
- Power redundancy
- Los Angeles
The Los Angeles data center has physical connection points with global telecommunications networks and infrastructures.
- Power redundancy
N+1 UPS system, eight 1500 kW generators and three 2000 kW generators for the building, shared UPS power capacity of 10,000 kW, 2N power density and DC power available.
- Cooling redundancy
N+1, Single membrane roof and Floor loading up to 125 lbs/ sq ft.
- On-site security
24/7 security, CCTV cameras, biometric and photo badge access, security doors for data center rooms and elevator authentication.
- Power redundancy
- Orlando
The privately owned and operated 25,000 square foot data center in Orlando guarantees maximum reliability for your company.
- Power redundancy
Caterpillar and Katolight diesel generators, 8,000-gallon fuel capacity for multiple redundant generators, 2 UPS in N+1 parallel configuration, redundant battery cabinets, and bypass switches.
- Cooling redundancy
Precise control of a constant temperature of 72°F/45% humidity, containment of servers in hot and cold aisles, total cooling capacity exceeding 500 tons, and dozens of high-powered air conditioning units.
- On-site security
On-site staff available 24/7; entry points with security system and access only by badge; biometric facial recognition; and video surveillance with more than 50 IP cameras.
- Power redundancy